SaphyRAD probes - Bertin Technologies

SaphyRAD probes

SaphyRAD probes

A wide range of radiation contamination probes are compatible with the SaphyRAD to perform detection and measurement of alpha & beta radiations.

Bertin instruments has developed a wide range of external probes dedicated to the SaphyRAD contamination monitor.

These smart probes allow for the assessment of small or large-area inspection to detect alpha, beta or alpha & beta radioactive contamination. The probes’ design is ergonomic and user friendly to ensure the workers’ safety. The beta probe for small-area detection includes an embedded contamination alarm monitor and a proximity sensor for an efficient and fast control. A floor stand allows the installation of a mobile checkpoint for clearance control.

Expert interview:

SaphyRAD, universal contamination meter with improved ergonomics

Julien Villert, Bertin’s Health Physics Product Manager, explains how the innovative probes of the SaphyRAD radiation contamination meter have been enhanced. Designed for EDF, this instrument has been enriched to suit the needs not only of the nuclear market, but also nuclear medicine, research and industry. Thanks to its alarm and distance control indicators, and its configurable radionuclide library, it is easy to use in all fields requiring radiation contamination detection, even by non specialists.

Get a quote for
SaphyRAD probes

Get a quote

Characteristics of the probes

Type of detection: 1 channel for α
Proximity sensor: YES
Radiation alarm: YES
Type of detector: ZnS
Surface of detector: 32 cm²
Sensitivity: 0.16 cps/Bq (239PU)
Measuring range: 0.01 à 100 Bq/cm²
Energy range: 3 à 8 MeV
Dimensions (L x W x H): 264 x 119 x123 mm
Weight: 600g

Characteristics of the probes

Type of detection: 1 channel for α,β (Global counting)
Proximity sensor: YES
Radiation alarm: YES

Type of detector: Double Geiger-Müller (GM) Pancake
Surface of detector: 31 cm²
Sensitivity: 0.21 c/s/Bq (36Cl)
Measuring range: 0.1 to 2,150 Bq/cm²

Energy range: 100 KeV to 2.2 MeV
Dimensions (L x W x H): 124x74x190 mm
Weight: 630g

Characteristics of the probes

Type of detection: 1 channel for α,β (Global counting)
Proximity sensor: YES
Radiation alarm: YES

Type of detector: Thin plastic scintillator
Surface of detector: 100 cm²
Sensitivity: 0.29 c/s/Bq (36Cl)
Measuring range: 0.1 to 1,000 Bq/cm²

Energy range: 100 KeV to 2.2 MeV
Dimensions (L x W x H): 293x119x121 mm
Weight: 600g

Characteristics of the probes

Type of detection: 2 measurement channels : 1 for α, 1 for β
Proximity sensor: YES
Radiation alarm: YES
Type of detector: ZnS + thin plastic scintillator
Surface of detector: 100 cm²

Sensitivity:
• α: 0.14 c/s/Bq (241Am)
• β: 0.23 c/s/Bq (36Cl)
Measuring range:
• α: 0.01 to 100 Bq/cm²
• β: 0.1 to 1,000 Bq/cm²

Energy range:
• α: 3 MeV to 8 MeV
• β: 100 KeV to 2.2 MeV
Dimensions (L x W x H): 293x119x121 mm
Weight: 600g

Characteristics of the probes

Type of detection: 1 channel for α,β (Global counting)
Proximity sensor: YES
Radiation alarm: YES

Type of detector: Thin plastic scintillator
Surface of detector: 170 cm²
Sensitivity: 0.29 c/s/Bq (36Cl)
Measuring range: 0.1 to 1,000 Bq/cm²

Energy range: 100 KeV to 2.2 MeV
Dimensions (L x W x H): 308x143x128 mm
Weight: 740g

Characteristics of the probes

Type of detection: 2 measurement channels : 1 for α, 1 for β
Proximity sensor: YES
Radiation alarm: YES
Type of detector: ZnS + thin plastic scintillator
Surface of detector: 170 cm²

Sensitivity:
• α: 0.15 c/s/Bq (241Am)
• β: 0.25 c/s/Bq (36Cl)
Measuring range:
• α: 0.01 to 100 Bq/cm²
• β: 0.1 to 1,000 Bq/cm²

Energy range:
• α: 3 MeV to 8 MeV
• β: 100 KeV to 2.2 MeV
Dimensions (L x W x H): 308x143x128 mm
Weight: 740g

Characteristics of the probes

Type of detection: 2 measurement channels : 1 for α, 1 for β and γ
Proximity sensor: YES
Radiation alarm: YES
Type of detector: ZnS + thick plastic scintillator
Surface of detector: 170 cm²

Sensitivity:
• α: 0.16 c/s/Bq (241Am)
• β: 0.28 c/s/Bq (36Cl)
Measuring range:
• α: 0.01 to 100 Bq/cm²
• β: 0.1 to 1,000 Bq/cm²

Energy range:
• α: 3 MeV to 8 MeV
• β: 100 KeV to 2.2 MeV
Dimensions (L x W x H): 308x143x128 mm
Weight: 740g

Reasons to choose SaphyRAD probes

User friendly embedded alarm & distance control indicator on the BCP31 probe

Ruggedized design for the nuclear industry

Versatile for contamination & measurement operations

ANY QUESTIONS? CONTACT AN EXPERT